Abaqus Volume II: I–Z Manuale Utente Pagina 182

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 628
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 181
*
M2
Subsequent lines (only needed if the D EPENDENCIES parameter has a value greater than six):
1. Seventh field variable.
2. Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the bending stiffness as a function of
temperature and other predefined field variables.
Data lines if the LINEAR par ameter is omitted:
First line:
1. Bending moment.
2. Curvature.
3. Temperature.
4. First field variable.
5. Second field variable.
6. Etc.,uptofivefieldvariables.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than five):
1. Sixth field variable.
2. Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the moment–curvature relationship as a
function of temperature and other p redefined field variables.
13.25–2
ABAQUS Version 6.1 Module:
ID:
Printed on:
Vedere la pagina 181
1 2 ... 177 178 179 180 181 182 183 184 185 186 187 ... 627 628